Immunity Test System

Immunity Test Sytem.png
Immunity Test Sytem1.png

Product Details
 

Features

Test Standards Complied

  • IEC61000-4-3 Ed3

  • IEC61000-4-6 Ed3?2008

  • EN61000-4-3?2010

  • EN61000-4-6 Ed3?2009

  • JIS C 61000-4-3?2012

  • JIS C 61000-4-6?2006

  • JEITA IT-3001 ect

 

Basic Function

Field Uniformity Measurement
A newly-added constant electric field method of IEC61000-4-3 can be selected; besides, a test substitution method with the frequency more than 1GHz that is defined corresponding to “Appendix J” can be also adopted.
(namely, “independent window method”)

  • Linear Verification of System

A linear verification for the test system that is newly added in IEC61000-4-3 can be executed. However, test systems that are incapable of meeting 2dB correction cannot use linear verification.

  • Measurement of Electric-Field Reference Value/ Measurement of Electric-Field Verification

Such measurements are performed to improve the measuring accuracy of the immunity measurement.

  • Immunity Measurement

Use the reference factor obtained by the uniformity measurement and the factor obtained by the electric-field verification to exert field strength for EUT and so as to perform immunity measurement.

  • Display Measuring Results

The system can debug the measuring result windows corresponding to the selected measuring types on which the measuring results are displayed.  Such windows can be further printed or the data of the windows can be saved in a Comma Separated Value (CSV) format.

  • Prepare Test Report

Output all data of various measurements into a test report with the specified format in a method of the automatic guide.

 

Lineup

Radiated Immunity Test System
The best test system is structured with the radiated immunity test software IM5/RS and VI5/RS as its core according to the customer’s requirement. TOYO can provide you with suggestions for system building according to your need and budget, including the configuration suggestions of instruments such as selective antenna, power amplifier, the filed probe, and radiofrequency cable, so as to generate a uniform electromagnetic field and an electromagnetic strength.

  • Comply with the Radiated Immunity Test Standard of the third version of IEC61000-4-3.

  • Automobile orders ECE R10, ISO11452-1/2, SAE, JASO.

  • Field strength: above 10V/m with a distance of 1m-3m.

  • Frequency: 80MHz-6GHz (maximum is 40GHz)

  • Uniformity measurement and automatic measurement functions of field strength.

  • The test software IM5/RS supports the latest Windows operating system.

 

  • Conducted Immunity Measuring System

Except for the optional signal amplifiers and radio-frequency amplifiers, TOYO can also provide you with a measuring system with the conducted immunity measuring software IM5/CS as the core according to your need; the measuring system comprises various optional coupling network systems, calibration measurement tools, and calibration program software.

  • Comply with the Immunity Test Standard of IEC61000-4-6

  • Test Level: above 10V (emf)

  • Frequency: 150kHz-80MHz (9kHz-230MHz)

  • Test Software IM5/CS supports the latest Windows operating system.

  • Simultaneously meet the requirements of automobile standards (BCI) ECE R10 and ISO11452-4.

 

System

Software

  • Immunity Measuring Software
    IM5/RS Radiated Immunity Test Software
    IM5/CS Conducted Immunity Test Software

  • EMC Measuring Software of Audio-Video Equipment
    IM5/A Audio Immunity Test Software
    IM5/V Television/Video Immunity Measuring Software
    IM9/S4 Shielding Effectiveness Measuring Software

  • EMC Measuring Software of Automobile
    VI5/RS Radiated Immunity Test Software for Automobile
    IM5/CS Immunity Test Software for Big Current Injection (BCI)